Anytime the bridge object definition is modified, the linked model must be updated for the changes to appear in the CSiBridge object-based model.
Define at least a layout line and a bridge deck section.
Click the Bridge > Bridge Objects > Expand arrow or on the Bridge Wizard form select the Bridge Object Definition item and click the Define/Show Bridge Objects button, to display the Define Bridge Objects form.
Use the following buttons on the form to complete the appropriate action:
Add New Bridge Object button. Click this button to display the Bridge Object Data form; use the form to add a new definition.
Add Copy of Bridge Object button.
Highlight the name of a previously defined bridge object definition.
Click the Add Copy of Bridge Object button to display the Bridge Object Data form. The form will be "pre-loaded" with the parameters specified for the definition selected in Step 1.
Make the necessary modification to the form, if any, to complete a new bridge object definition.
Modify/Show Bridge Object button.
Highlight the name of a previously defined bridge object definition.
Click the Modify/Show Bridge Object button to display the Bridge Object Data form.
Use the form to modify the definition without adding a new definition.
Delete Bridge Object button.
Highlight the name of a previously defined bridge object definition.
Click the Delete Bridge Object button to delete the definition.
See Also