Form: Perform Bridge Superstructure Rating
The Design/Rating >Load Rating > Run Rating command starts the load rating process.
Use the Bridge Wizard or the commands on the various tabs to create a bridge model. At least a layout line and deck section must be defined so that a bridge object can be defined. Specify Load Patterns and Load Cases that are then combined in Load Combinations, which are generated automatically by the program to satisfy the limit state(s) specified in the code selected using the Design/Rating > Load Rating > Preferences command; load combinations also can be user specified.
Use the Design/Rating > Load Rating > Rating Requests command to specify the loading to be analyzed.
Click the Design/Rating > Load Rating > Run Rating command to display the Perform Bridge Superstructure Rating form. Use that form to set the action for individual rating requests or for all rating requests simultaneously.
Highlight the rating request and click the Rate/Do Not Design button to toggle the rating on and off. When Run displays in the Action List, the rating will run.
Delete a Rating Request
Highlight a Request Name and click the Delete Rating for Request button to delete the rating for the selected request. Use the Delete All Ratings button to delete all ratings simultaneously. If rating for one request is deleted, the status of the rating will be set to Not Run.
Important: When ratings are deleted, you will be asked for confirmation. After a rating has been deleted, it cannot be recovered until rating is run again. Clicking the Cancel button will not undelete them. Also, a rating request can not be deleted as described here until after the rating has been run.
Note: To delete a rating request, click the Design/Rating > Load Rating > Rating Requests command to access the Bridge Rating Requests {Code} form. Highlight the request to be deleted and click the Delete Request button.
Use the Rate/Do Not Rate All button to toggle all requests simultaneously.
Click the OK button and the action settings will be saved but the rating will not run.
Click the Cancel button and the action settings will be left unchanged.
Click the Rate Now button and the rating requests set to Run will be run.