Form: Automatic Rectangular Mesh Options (for Walls)
Click the Analyze menu > Automatic Rectangular Mesh Settings for Walls command to access the Automatic Rectangular Mesh Options (for Walls) form.
Note: The Automatic Rectangular Mesh Options (for Walls) form also displays when the Assign > Shells >Wall Auto Mesh Options command is used to access the Shell Assignment -Wall Auto Mesh Options form and the Advanced - Auto Rectangular Mesh Settings button is clicked.
Use the form to specify the Approximate Maximum Mesh Size. The rectangular mesh lines will be spaced according to the distance specified in the edit box.
The meshing is applied to shell objects that use auto rectangular meshing either by default or as part of an assignment (see Note above).
Use the Reset Defaults button to clear previously specified mesh settings.