Hinge Property Data Form

Use the Hinge Property Data form to specify the property name and the hinge type, and to access other forms that can be used to specify parameters for the property definition.

The Axial P, Shear V2, Shear V3, Torsion T, Moment M2 and Moment M3 frame hinge types are all uncoupled. They can exist in the same frame hinge property, but no interaction between them exists. Only the Shear V2 can exist in a wall hinge property.

The interacting P-M2-M3 frame hinge type (interacting P-M3 wall hinge type) is a coupled hinge property. It can exist with uncoupled Shear V2, Shear V3, and Torsion T hinge types, but not with uncoupled Axial P, Moment M2, or Moment M3 types.

The forms that display when the Hinge Type is Deformation Controlled (Ductile) and  Axial P, Shear V2, Shear V3, Torsion T, and Moment M2, and Moment M3 are described in the Hinge Property Data for Property Name Form - Deformation Controlled topic.

The forms that display when the Hinge Type is Deformation Controlled (Ductile) and interacting (P-M3, P-M2, M2-M3, P-M2-M3) are described in the Hinge Property Data for {Property Name} - Interacting {Hinge Type}   topic.

The forms that display when the Hinge Type is Deformation Controlled (Ductile)  and Fiber are described in the Hinge Property Data for {Name} - Fiber  topic.

The forms that display when the Hinge Type is Force Controlled (Brittle)  are described in the Hinge Property Data for Property Name Form - Force Controlled  topic.

 

Access the Frame Hinge Property Data form as follows:

  1. Click the Define menu > Section Properties > Frame/Wall Nonlinear Hinge command to access the Define Frame/Wall Hinge Properties form. Then do one of the following: