Display Punching Check

Toolbar button:

Use the Design menu > Concrete Slab Design > Display Punching Check command to display in the active window the punching shear ratios, or the required shear reinforcing if the joint had previously been selected and the Design menu > Concrete Slab Design > View/Revise Punching Check Overwrites command was used to allow reinforcement.

Punching shear ratios are displayed as a ratio of maximum calculated shear with respect to capacity. A ratio above 1.0 would indicate capacity was exceeded somewhere along the critical section. The ratio is displayed for each column (and restrained joint) and each joint load.

See Also

Punching Shear Design Overwrites form