Initial Conditions Nonlinear

For nonlinear analyses, specify the initial conditions at the start of the analysis:

Important: An unlimited number of sequences or branches of nonlinear load cases can be created. However, be sure that the first case in every sequence or tree of nonlinear cases starts from Zero Initial Conditions.

When continuing from the state at the end of the nonlinear case, the following restrictions apply:

Note: When continuing from the state at the end of a nonlinear case, all applied loads specified for the present load case are incremental, i.e., they are added to the loads already acting at the end of the nonlinear case.

When considering a sequence of FNA cases, static loading may be applied by defining a case in which:

Note: Linear time-history load cases always start from Zero Initial Conditions.

Display the Initial Conditions options on the Load Case Data form as follows:

  1. Click the  Define menu > Load Cases command to display the Define Load Cases form.

  2. Click the Add New Load Case button, or highlight a previously defined case and click the Add Copy of Load Case, or Modify/Show Load Case button, to display the Load Case Data form.

  3. Set the Load Case Type to Static or Time History and the Analysis Type to Nonlinear.