Select a slab object(s) and click the Design menu > Slab Design Overwrites > Finite Element Based command to access this form and apply overwrites to the selected slab object(s).
Note: For finite element based slab design, the reinforcing is assumed to be placed in the slab object local 1 and 2 axis directions. At drop panel locations, the reinforcing is assumed to be placed in the drop panel object local 1 and 2 axis directions.
Rebar Material. Select the rebar material to use in the design strip(s) from the drop-down list of previously defined materials. Rebar material may be defined, edited or reviewed by clicking the Materials form.
button to access theCover. Choose from the following options to specify the concrete cover over the rebar for the selected strip(s):
From Preferences: Select this option if the cover should be as set in the Design menu > Design Preferences command. SAFE applies the clear cover specified in the Design menu > Design Preferences command to the outer layer and assumes that the inner layer is located directly inside the outer layer for both top and bottom rebar. This is the default setting.
Specified to Center of Steel: Select this option to explicitly locate the rebar by specifying the distance to the center of steel in the Direction 1 and Direction 2 Top Cover and Bottom Cover edit boxes.
Live Load Reduction Specify a factor to reduce the live load forces used in slab design; most codes allow for live loads to be reduced based on tributary area calculations. The resultant forces in the selected slab object will be multiplied by the Reduced Live Load Factor when used for design. The only forces affected will be those that result from load cases associated with load patterns with a type of REDUCIBLE LIVE, or load cases that have been user identified as REDUCIBLE LIVE using the Load Case Data form.
button on theThe default value for the Reduced Live Load Factor is 1, which means that there is no reduction; a value of 0.75 would mean that the forces are decreased by 25%.
Design Option. Check the Design This Slab Object check box if design should be performed for the selected slab. To ignore post-tensioning during design, check the Ignore PT When Designing This Slab Object check box.
Note: Design strip information can be accessed by expanding the tree under Objects > Design Strip Objects on the Model tab in the Model Explorer window.
See Also