Finite Element Based Slab Design Overwrites Form

Select a slab object(s) and click the Design menu > Slab Design Overwrites > Finite Element Based command to access this form and apply overwrites to the selected slab object(s).

Note:  For finite element based slab design, the reinforcing is assumed to be placed in the slab object local 1 and 2 axis directions. At drop panel locations, the reinforcing is assumed to be placed in the drop panel object local 1 and 2 axis directions.

The default value for the Reduced Live Load Factor is 1, which means that there is no reduction; a value of 0.75 would mean that the forces are decreased by 25%.

Note: Design strip information can be accessed by expanding the tree under Objects > Design Strip Objects on the Model tab in the Model Explorer window.

See Also

Strip Based Slab Design Overwrites Form