Use the Tabulated Tendon Profile form to review the tendon profile.
Tabulated Data spreadsheet. The Point, X, Y, Z, and Tendon Distance data in this spreadsheet reflect the graphical layout achieved using the various options on the Bridge Tendon Data form. The data in this spreadsheet is provided for review purposes only and cannot be edited. To change the data, click the Done button to return to the Bridge Tendon Data form and use that form to make the necessary changes to the tendon profile.
Edit menu > Copy command. The Edit menu > Copy command available on this form can be used to copy the profile data to the Windows Clipboard for pasting into another program, such as Excel.
Maximum Tendon Discretization Length for Tabular Data options. Choose to use the previously defined discretization length or specify another.
Discretization Length Defined for Tendon option and display box. The value displayed in this display box reflects the value specified on the Prestress Loss Parameters form in the Max Discretization Length edit box.
Other Discretization Length and edit box. When this option is selected, enter a value in the edit box to specify the discretization length for the tendon.
Update Tabular Data button. After changing the option for Maximum Tendon Discretization Length for Tabular Data, click this button to update the Tabular Data spreadsheet and review the revised profile data.
Note: After specifying a value in the Other Discretization Length edit box, clicking the Update Tabular Data button, and reviewing the resulting data, it is necessary to return to the Bridge Tendon Data form and enter a value in the Max. Discretization Length edit box to change the tendon discretization. The Tabulated Tendon Profile form is for review purposes only.
Tendon Name display box. This is the name assigned to the tend definition using the Bridge Tendon Data form.
Units drop-down list. Use the displayed units or select new units from the drop-down list.
See Also
Access the Tabulated Tendon Profile form as follows:
Alternatively, the following approach can be used if the form is being used when the Bridge Object is being defined or reviewed.
|